The bipolar conductivity detector without range conversion has a huge signal range, and can realize direct simultaneous detection in the concentration range of 5 ppb-200 ppm without manual range selection and switching;
As a special halogen-free detection instrument, JIC-510 ion chromatograph has been widely praised. Based on the latest needs of users, it is positioned as a new generation of instruments for halogen control and detection in electronic and electrical, production and processing industries.It can simply, quickly and conveniently detect the contents of fluorine (F), chlorine (Cl), bromine (Br) and iodine (I) under halogen-free control。
The bipolar conductivity detector without range conversion has a huge signal range, and can realize direct simultaneous detection in the concentration range of 5 ppb-200 ppm without manual range selection and switching;
The eluent is preheated, and the column temperature is more stable and the data is more consistent
It is necessary to clean and maintain the system when changing the eluent or stopping for a long time. This function can automatically switch between two different solvents, saving manual and cumbersome operations;
Fully automatic: the overall design of fully automatic instruments such as automatic start-up, automatic shutdown, automatic maintenance, automatic post-pump cleaning, automatic triggering of sample injection sequence and automatic detection of eluent;
Fully intelligent: a fully intelligent sensing system of instrument state is realized by using multiple self-developed sensors and combining software and hardware organically;
Automatic range: bipolar conductivity detector without range conversion, which has a great signal range, and can realize direct simultaneous detection in the concentration range of 5 ppb-200 ppm without manually selecting and switching the range;
Eluent detection: the high-precision non-contact sensor detects the eluent in the pipeline in real time, and can alarm when there is no eluent and stop the pump according to the preset time without any additional operation and setting;
Liquid leakage alarm: the high-sensitivity optical sensor can be detected even after a small amount of liquid leaks, and the system will send out an acousto-optic alarm and execute the suppressor power-off and pump stop procedures according to the preset time;
Automatic post-pump flushing: the system needs to be cleaned and maintained when the eluent is changed or it needs to be stopped for a long time. This function can automatically switch between two different solvents, saving manual and cumbersome operations;
Automatic switching of flow path: the system needs to be cleaned and maintained when the eluent is changed or the system needs to be shut down for a long time. This function can automatically switch two different solvents, saving manual and cumbersome operations;
Simple and convenient operation: professional software, simple operation;
Eluent preheating: Eluent enters the column temperature box for synchronous preheating before entering the whole chromatographic system, so as to avoid pump pressure fluctuation and long baseline balance time caused by the temperature difference between the ambient temperature and the system。
The main application industries are electronic appliances, PCB boards, wires and cables, new energy, medical devices, toy plastics, ink coatings, packaging materials and so on.
Response tests: fluorine (f), chlorine (CL), Australia (Br) and iodine (l)The analysis and detection can be completed within 20 minutes in one injection, which is convenient and rapid, and it is an international standard analysis method。