Online consultation Online consultation

WhatsApp WhatsApp
TOP
Home - Products - RoHS1.0 - JXF-8000
JXF-8000
Product Overview:

JXF-8000 is a high-end spectrometer model in the CONOMA series of products under Junhuiteng, equipped with a dual radiation protection system; Humanized operation interface; Comprehensive application of experience coefficient method and basic parameter method V1.0 analysis software. The scope of element testing is from S-U. It can detect lead (Pb), mercury (Hg), cadmium (Cd), total bromine (Br), and total chromium (Cr) in regulations, as well as chlorine (Cl) and bromine (Br) elements in halogen-free directives. The carefully designed open working curve function is particularly suitable for factory process control of various materials. Compared to traditional common instruments in the industry, this model has the advantage of quickly analyzing and identifying material anomalies in the current industry. It is an efficient and accurate system solution based on fully addressing customer HSF control demands. The principle of this solution is clear, the method is feasible, and the effect is significant.

Fast ": Through a large number of experiments, the standard deviation of different materials at different contents has been provided, and a scientific mathematical model has been established based on this result. A report that complies with the IEC62321 standard can be provided in a short period of time, which meets the demand for accountability (i.e. due diligence exemption).



File Download
  • Analyze all heavy metal elements in S-U

  • Quick testing

  • Coating thickness measurement function

  • Industry standard drafting unit

  • Product advantages
    Precision: Open working curve
    Provide an open working curve platform, where users can freely configure working curves and add standard sample data to meet higher testing requirements or adapt to later extensions of environmental protection directives;
    Quick: Unique Full Spectrum Comparison Function

    Real time tracking of supplier material abnormalities and timely warning have unparalleled advantages in RoHs/halogen-free and supplier control.

    Safety: Dual X-ray protection

    Dual X-ray protection (software, hardware, maze design) ensures the personal safety of operators and radiation injuries caused by accidental operations;

    Design of sample room

    The design of the large sample room allows for open testing of infinitely large samples (with protective mechanisms), providing more space compared to traditional models;

    Adopting a new type of optical path design

    By adopting a new optical path design, the detection limit of chlorine (Cl) element has been reduced;

    Tailored harmful substance detection plan

    Provide an open working curve calibration platform that can tailor hazardous substance detection solutions for users;

    Leading XRF analysis software

    The internationally leading XRF analysis software integrates analysis methods such as empirical coefficient method and basic parameter method (FP method);

    Multiple report output formats (Excel, PDF, etc.)

    Custom test report output formats (Excel, PDF, etc.) can be customized according to user requirements to meet various statistical and formatting requirements of the factory; Multi language (English, Simplified Chinese, Traditional Chinese, etc.) software interfaces are available for selection;

    Product Features
    • Accurate testing can be conducted on hazardous elements and halogen-free requirements (Pb, Cd, Hg, Br, Cr, Cl) in the RoHS directive; Pre set multiple working curves, covering substrate types such as metal, PE, PVC, aluminum magnesium, solder, copper alloy, etc., to meet the requirements of users' routine measurements;
    • Accurate data processing method: The filter system, which is precisely configured based on the basic parameter method, significantly improves the peak to background ratio. Combined with a series of advanced spectral processing methods, it greatly improves the detection accuracy of characteristic spectral lines. Based on this, the empirical coefficient method is used for further correction to achieve extremely high precision and accuracy in the test data;
    • Data management: The specialized report generation, query printing, operator hierarchical authorization, and other functions supported by the database greatly facilitate enterprise management;
    • Comprehensive safety interlock function: In conjunction with hardware circuit protection measures, it automatically cuts off X-rays in the event of unsafe operations to ensure that operators are not harmed;
    • Intelligent software protection: avoids damage to the spectrometer caused by improper operation and extends the service life of the instrument.
    • Stability self check function: It can automatically detect the current stability of the instrument in real time;
    Applictation scope

    After years of algorithm experience accumulation, JXF-8000 has been designed and developed rationally, with accurate testing and easy operation. It is convenient for RoHS limited testing, material element analysis, coating thickness analysis, and testing in accordance with global hazardous substance regulations and testing methods. The main application industries are electronic appliances, large and small household appliances, IT and communication equipment, lighting equipment, hardware materials, soldering PCB and other industries.

    The JXF-8000 analyzer has been recognized as a screening tool for testing consumer products to determine whether they comply with the following global hazardous substance regulations and testing methods:

    Japan RoHS
    US Consumer Product Safety Improvement Act (CPSIA) (HR4040)
    China RoHS Directive (ACPEIP)
    EU RoHS Directive (2011/65/EU)
    Korea RoHS Directive
    US Halogen Free Restriction Directive
    California Proposition 65
    Standard Operating Procedure for CPSC-CH-E1002-08 SOP in the United States
    Technical Parameter
    Detection range
    Meet the requirements of the EU RoHS directive for detecting harmful elements such as lead (Pb), cadmium (Cd), mercury (Hg), total chromium (Cr), and chlorine (Cl) and bromine (Br) in halogen-free directives; Optional testing: composition analysis of ferroalloys and copper alloys, thickness measurement of metal coatings (analysis of 1-2 layers, minimum detection limit of 0.005um function, etc.)
    test method

    Comply with IEC62321,GB/T26125-2011 Standard detection methods, etc.

    Test element range
    Elements in S-U satisfy qualitative and quantitative analysis.
    Test sample type
    Solid, powder and liquid


    Detection content range

    1ppm-99.99%

    Lower detection limit

    Pb≤5ppm,Cd/Cr/Hg/Br≤2ppm,Cl≤50ppm

    Measuring time

    10~200s(Time adjustable)

    repeatability
    ≤0.5%
    stability
    ≤0.5%
    collimator
    Φ0.3mm、Φ1mm、Φ3mm、Φ5mm、Φ8mm
    light filter
    Automatic switching of five kinds of composite filters
    CCD observation
    8 megapixel high definition CCD
    detector

    American Si-PIN detector (X-123DP5FW6 version)

    resolution ratio

    140±5 KeV

    Cooling method

    Electric refrigeration, high stability and accuracy, no need for liquid nitrogen

    Detection window
    Beryllium window
    Spectrum processing system
    Digital-to-analog conversion (DP5), channel address interval 2048, counting 500~8000cps.
    X-ray tube target
    Mo Target, other targets are optional.
    X-ray tube window
    Be window
    Cooling mode
    Silicone grease cooling
    service life

    ≥15000h

    Equipment structure
    Lead-containing plate is radiation-proof, with mechanical structure and alarm prompt function.
    security
    Fully enclosed metal cabinet and anti-leakage protection switch better protect the personal safety of operators.The overall appearance is simple and generous, the internal ventilation is excellent, and electromagnetic interference is effectively shielded.
    X-ray radiation protection function
    Triple-ray protection system (software, hardware, labyrinth design), automatic warning system for opening test, in line with national standards (reference standard: 《Basic Standards for Protection of Ionizing Radiation and Safety of Radiation Sources》 (GB 18871-2002), and the inspection standard is not more than 0.5μ SV/hr.
    Input power supply

    AC110V~250V,50/60Hz

    rated power
    400W
    operating ambient temperature
    temperature10—30℃
    Relative humidity of working environment
    40%~80%(No condensation)
    Instrument size
    520mm(W)*400mm(D)*355mm(H)
    Sample cavity size
    420*320*65mm,Can open the lid to test infinite samples (with protection mechanism)
    net weight
    roughly41.8Kg
    Configuration List
    Host configuration
    detection system
    1
    Type: Si PIN detector

    Brand: Amptek from the United States (imported with all original accessories)

    Be window thickness: 1mil (0.0254mm)

    Best resolution: 140 ± 5eV

    System peak to back ratio: ≥ 6200/1

    Energy response range: 1keV~40keV

    Recommended count rate: 5000cps


    X-ray tube
    1

    voltage: 0 ~ 50 kV

    maximum current: 1.0 mA

    Maximum power: 50 W

    filament voltage: 2.0V

    filament current: 1.7 A

    Ray extraction angle:12°

    Target material:Mo

    X-ray window:Bewindow

    high voltage
    1

    INPUT VOLTAGE: DC +24V±10%

    Input Current:4.25A(maximum)

    Output voltage: 0 -50KV & 1mA

    Maximum power:50W

    Voltage regulation:0.01% (From no load to full load)

    load regulation:0.01% (From no load to full load)

    ripple voltage:Under the premise of output rated voltage, the peak value of ripple voltage is 0.25% of the highest output voltage。

    8-hour stability:≤0.05%

    micro-feeding unit
    1

    The load testing platform has a fine-tuning device located outside the instrument, combined with an 8-megapixel high-definition CCD, to accurately locate the test sample and prevent vibration caused by closing the sample cover after the sample is placed, which may change the testing position and result in inaccurate testing;

    High resolution CCD
    1

    An 8-megapixel high-definition CCD camera can effectively observe the condition of the testing area in real time and take photos of the materials as part of the inspection report。

    COOLING SYSTEM
    1
    Efficient 3D heat dissipation system, providing significant reliability and stability of the instrument。
    Radiation safety system
    1
    Triple radiation protection system (software, hardware, maze design), automatic warning system for open lid testing
    RoHS specific analysis software
    1
    Surrounding supporting equipme
    business computer
    1
    Color Printer
    1
    Standard Sample
    1
    Silver calibration sample
    1
    Sample Cup
    2
    Test film
    200
    Standard documents
    Operating Instructions
    1
    certificate of conformity
    1
    guarantee card
    1
    Radiation safety inspection report
    1